Sign In | Join Free | My burrillandco.com
Home > HMI PLC All In One >

Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel

Shenzhen Coolmay Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel from wholesalers
     
    Buy cheap Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel from wholesalers
    • Buy cheap Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel from wholesalers
    • Buy cheap Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel from wholesalers

    Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel

    Ask Lasest Price
    Brand Name : Coolmay
    Model Number : QM3G-70KFH
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 15000 Units Per Week
    Delivery Time : 3-8 works days
    • Product Details
    • Company Profile

    Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel

    Coolmay 4-6W HMI PLC All-In-One Analog Module RS232 RS485 7 Inch HMI Panel 64MB 800*480 DC24V


    The all-in-one solution is to integrate the controller, operation interface, input/output, analog input/output, high-speed counting/pulse and communication port into a compact unit to meet the needs of customer equipment automation control.


    PRODUCT DESCRIPTION of HMI PLC ALL IN ONE


    Feature:

    1. Super functions.PLC compatible with FX3G/FX3U/FX3S PLC.It operate fast.
    2. Highly integration.The digital points are 30 inputs and 30 outputs at most.The digital output can be transistor,relay or mixed output.Analog can reach up to 16 input and 8output.It has 2PLCCOM port(Rs232and USB Port).1 downloading port on HMI
    3. Support several high-speed counting and high-speed pulse.Acceleration and deceleration are independent.The total high-speed counting and pulse can not exceed 480KHz
    4.32K steps program capacity.32K power-off retentive registers.support interrupt.linear and circular interpolation.PID self-adjusting
    5. Special encrvotion.Set password as 12345678 to thorouahly prevent readina dataPLC only supporls 8-bit password encryotion
    6. PLC is compatible with programming software GX Developer8.86Q and GX Works2and HMl is mView software.
    7. The network module can be selected accordina to customer reauirements to realize remote control More models are supported to customize if bulk order.


    ModelQM3G-70KFH
    Dimension226*163*35.6mm
    Cutout size217*154mm
    Input24VDC
    Power Consumption4-6W
    HMI
    Feature60K colors resistive touch screen, supports portrait display
    Type7.0"TFT
    Display size154*87mm
    Resolution(pixels)800*480
    RAM64MB (Please inquire if requires storing historical data)
    ROMNOR Flash 8MB
    CPU32bit CPU 408MHz
    COM portsType-B HMI download port (can download PLC program through the USB penetrating function), RS232
    SoftwareCoolmay TPWorks HMI Programming Software

    PLC:


    I/O level -Input:

    -Passive NPN, public terminal isolated

    -Transistor output: Low level NPN, COM connect to negative

    -Relay output: Normally open dry contact

    DO type and load:

    -MT: 2A/point, 4A/4 points COM; MT: 0.5A/point, 0.8A/4 points COM, 1.6A/8 points COM

    -MR: 2A/point, 4A/4 points COM, 5A/12 points COM.

    High-speed counting:

    Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10KHz

    High-speed pulse(Only for MT models):

    8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.

    High-speed counting + high-speed pulse < 480KHz

    COM port:

    1x mini USB, 1x RS232, 1x RS485

    Software:

    Compatible with GX Developer8.86 and GX WORKS 2


    FAQ

    1.Precautions of using PLC transistor and relay
    The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
    The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
    2.Precautions of Coolmay PLC output type selection
    MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
    The main differences between transistor output and relay output are:
    (1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
    (2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
    (3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
    (4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.

      Quality Coolmay 4-6W HMI PLC All In One Analog Module RS232 RS485 7 Inch HMI Panel for sale
      Inquiry Cart 0
      Send your message to this supplier
       
      *From:
      *To: Shenzhen Coolmay Technology Co., Ltd.
      *Subject:
      *Message:
      Characters Remaining: (0/3000)